Most problems with a refurbished server show up in the first days of use, and nearly all of them are easy to diagnose because enterprise servers log their own faults. This guide covers the issues we see most often on refurbished Dell PowerEdge and HPE ProLiant servers, how to find the cause, and how to fix each one.
Start with the server’s own logs
Before you open the case, read what the server has already recorded. Dell PowerEdge servers keep a System Event Log and a Lifecycle Log in iDRAC. HPE ProLiant servers keep the Integrated Management Log (IML) in iLO. Both list failed drives, memory errors, power supply faults, fan failures and temperature warnings with a time stamp and the component location.
Common refurbished server issues and fixes
| Symptom | Likely cause | What to do |
|---|---|---|
| Amber light on a drive, or RAID shows “degraded” | Failed or failing hard drive | Replace the drive with a compatible model and let the array rebuild. Check the rebuild completes in the RAID controller. |
| Memory error in the log, or the server shows less RAM than installed | Faulty or unseated DIMM, or incorrect slot population | Reseat the module, check the slot population rules for your model, and replace a DIMM that keeps logging errors. |
| Power supply fault, or the server says redundancy is lost | Failed PSU, or one PSU not connected | Check both power cords and the outlet, then replace the failed PSU. Hot-swap PSUs can be changed while the server runs. |
| Fans run at full speed all the time | Failed fan, missing blanking panel, high temperature, or a non-standard PCIe card | Check the log for fan or temperature errors, fit all blanks and covers, and check whether a third-party card is causing a higher fan profile. |
| Server shuts down or throttles | Overheating | Improve airflow, clean intakes and keep the room cool. See our guide to keeping a server cool. |
| Operating system installer cannot see the disks | Missing RAID controller driver, or no virtual disk created | Create a virtual disk in the RAID controller first, then load the controller driver or use Dell Lifecycle Controller or HPE Intelligent Provisioning to deploy the OS. |
| Date, time or BIOS settings reset after power loss | Flat CMOS battery | Replace the coin cell battery and set the BIOS again. |
| Server will not boot from the disk | Boot mode mismatch (UEFI vs legacy BIOS) or wrong boot order | Match the boot mode to how the OS was installed and set the boot order. |

How to troubleshoot step by step
- Read the log. iDRAC or iLO usually tells you exactly what failed and where.
- Check the obvious. Power cords, network cables, seated drives and modules, and that covers and blanks are fitted.
- Check firmware. Mismatched BIOS, controller and drive firmware can cause odd behaviour. Read our guide to firmware updates.
- Run the built-in diagnostics. Dell servers include ePSA or SupportAssist diagnostics in the Lifecycle Controller, and HPE servers include diagnostics in Intelligent Provisioning.
- Swap one part at a time. Change a single DIMM, drive or PSU and test again, so you know which part fixed it.
How to prevent problems
- Run drives in RAID and keep a spare drive on hand. Our RAID guide explains the options.
- Use redundant power supplies on a UPS, especially during load shedding.
- Keep the room cool and dust-free.
- Update firmware during planned maintenance windows.
- Monitor the server so you see problems early. Compare free tools in our server monitoring guide.
- Back up regularly and test that restores work.
When to call for help
Contact your supplier if a part fails within the warranty period, if the same error keeps returning after you replace a part, or if the server will not complete its power-on self test. Have the log entry, the server model and the service tag or serial number ready. For general upkeep, follow our refurbished server maintenance guide.
Frequently asked questions
What is the most common problem with refurbished servers?
Hard drive failures are the most common hardware issue on any server, new or refurbished, because drives have moving parts. Running drives in RAID means one drive can fail without data loss.
How do I check a server for hardware faults?
Open the management interface, iDRAC on Dell or iLO on HPE, and read the event logs. They record failed drives, memory errors, power supply faults and temperature warnings.
Why are my server fans so loud?
Fans run at full speed briefly at start-up, which is normal. If they stay loud, check the log for a failed fan, high temperatures, missing blanking panels or a third-party PCIe card that triggers a higher fan profile.
Why can my operating system installer not see the server disks?
Usually no virtual disk has been created in the RAID controller, or the installer needs the controller driver. Create the virtual disk first, then use Dell Lifecycle Controller or HPE Intelligent Provisioning, or load the driver manually.
Need a replacement drive, memory or power supply? Browse our server parts, server hard drives and server memory, or contact our team.