Do Refurbished Servers Consume More Power? Comparing Efficiency

Energy Efficiency

A common worry about refurbished servers is the electricity bill. The honest answer is that a refurbished server uses exactly as much power as the same model did when it was new. What matters is the generation and the configuration: an older server doing the same job may use more power than a newer one, and extra drives, CPUs and power supplies all add to the total.

Quick answer: refurbished servers do not use more power because they are refurbished. Power use depends on the server generation, the processors, the number of drives and how busy the server is. Choosing a newer generation, the right CPU and only the drives you need keeps consumption down.

What drives server power consumption

FactorEffect on powerHow to reduce it
Server generationNewer platforms usually do more work per wattChoose Dell 14th generation or HPE Gen10 where the budget allows
ProcessorsHigher-TDP and dual CPUs draw morePick a CPU sized to the workload; one socket may be enough
Hard drivesEach spinning drive adds a few wattsUse fewer, larger drives or SSDs
MemoryMore DIMMs add some powerInstall what you need, with room to grow
Power supply efficiencyEfficient PSUs waste less as heatUse the PSU rating your server supports and size PSUs sensibly
WorkloadBusy servers draw more than idle onesConsolidate workloads with virtualisation
server energy efficiency

How to estimate the running cost

Use this formula: average watts × 24 hours × 30 days ÷ 1 000 = kWh per month. Multiply by your electricity tariff.

Average drawkWh per monthCost per month at an example tariff of R3/kWh
100 W72 kWhR216
150 W108 kWhR324
250 W180 kWhR540
Good to know: the R3 per kWh tariff above is only an example to show the maths. Use the rate on your own municipal or Eskom bill, which varies by area and tariff.
Pro tip: iDRAC on Dell and iLO on HPE show real-time and historical power use. Check the actual draw of your server under normal load before calculating costs, rather than using the power supply rating.

Power supply rating is not power use

A server with two 750 W power supplies does not use 1 500 W. The rating is the maximum each supply can deliver, and the second supply is usually there for redundancy. Typical draw is far lower and depends on configuration and load.

Watch out: size your UPS for the server’s actual peak draw plus your network equipment, not the power supply ratings, but leave headroom. An undersized UPS will shut everything down at the first long outage.

Refurbished vs new: the full picture

A new server may use less power for the same work, but it costs much more up front. For many small businesses, the price difference pays for years of electricity. Read our comparison of refurbished vs new servers, and our guide to sustainable server management for ways to cut energy use.

Frequently asked questions

Do refurbished servers use more electricity?

No more than the same model when new. Older generations can use more power for the same work than newer ones, so the generation matters more than being refurbished.

How much power does a server use?

It varies widely with model, CPUs, drives and load. Check the real figure in iDRAC or iLO rather than relying on the power supply rating.

How do I reduce server power consumption?

Choose a newer generation, size the CPU to the workload, use fewer or solid-state drives, consolidate with virtualisation, and keep the server cool.

What size UPS do I need for a server?

Size it for the actual peak draw of the server and network equipment, with headroom, and for the runtime you need to shut down cleanly.

Want an efficient server? Dell PowerEdge 14th gen and HPE ProLiant Gen10 models offer good performance per watt, or ask our team.